Skip to main content
Design DocumentAnalog

ADEMA124/ADEMA127 Calibration Guide

Calibration guide for ADEMA124/ADEMA127 energy measurement ICs. Details ADC/DSP configuration and gain/phase calibration for voltage dividers, CTs, and Rogowski coils.

View design document

Overview

This reference manual provides a detailed technical guide for the calibration of Analog Devices ADEMA124 and ADEMA127 energy measurement systems. It outlines the necessary configurations for ADC timing and channels, including sinc filter decimation and DSP settings optimized for different sensors such as voltage dividers, shunts, current transformers (CT), and Rogowski coils. The document covers gain calibration procedures for both voltage and current channels, phase angle adjustment techniques, and software-level corrections including RMS offset and electrostatic coupling correction to ensure high-accuracy energy metering data.

Use Cases

  • Energy metering system design
  • Power monitoring equipment calibration
  • Industrial power measurement systems
  • Voltage and current sensor signal conditioning

Topics

ADEMA124
ADEMA127
Analog Devices
energy measurement
ADC calibration
DSP configuration
Rogowski coil
current transformer
gain calibration
phase angle calibration

Referenced Parts

ADEMA124

Analog Devices

ADEMA124/ADEMA127 Calibration Guide

ADEMA127

Analog Devices

ADEMA124/ADEMA127 Calibration Guide

ADEMA124/ADEMA127 Calibration Guide | Design Resources